Gas detection compliance is no small feat and CES services is here to manage your entire compliance program, ensuring yearly compliance and safe employees. CES will provide all required Annual Calibration Testing, Document Production and Retention, Using Certified Technicians, all in compliance with NFPA 720 and specific manufacturer guidelines. CES Covers the entire Northeast for calibration services and have provided a few local area laws below:


data-scientist.jpg

Who We Are...

Award-51SMaller2smaller.png

We Bring You The Best Service

260x260-serviceicon.png

With the Most Qualified Team

xkerijlzcuraiouyladwSmaller.png

To Guarantee Your Safety!


NFPA 720 Establishes Clear Guidelines for Yearly Facility Gas Detection Compliance:

diploma-roll_318-59066.jpg

Required Certified System Technician Qualifications

documentazione_software_vbox.png

Testing Results and System Document Policies

tools.gif

Annual System Testing Requirements


Net-Safety-Calibration-Kit-360.jpg

Annual Calibration Testing Procedures

  • Verify correct receipt of alarm, supervisory, and trouble signals (inputs); operation of evacuation signals and auxiliary functions (outputs); circuit supervision, including detection of open circuits and ground faults; and power supply supervision for detection of loss of ac power and disconnection of secondary batteries
  • Verify correct receipt of alarm, supervisory, and trouble signals (inputs); operation of evacuation signals and auxiliary functions (outputs); circuit supervision, including detection of open circuits and ground faults; and power supply supervision for detection of loss of ac power and disconnection of secondary batteries
  • For all system detectors installed after January 1, 2012, carbon monoxide tests shall be performed at initial acceptance and annually by the introduction of carbon monoxide into the sensing chamber or element. An electronic check (magnets, analog values, etc.) is not sufficient to comply with this requirement.
 
iStock_000016136100XSmall_4.jpg

Document Compliance and Retention

  • Building layout, gas detection system layout, and system equipment documentation are all required to be maintained and updated yearly
  • Yearly and all prior system certification documentation is required. Record of all inspections, tests, and maintenance documentation is to be maintained. Semi and Annual test form document must be completed. Upon request hard copies of all records shall be made 
  • The system shall be clearly identified by a placard sticker, or other means to indicate the next regularly scheduled inspection period
  • It shall be the responsibility of the owner to maintain these records for the life of the system and to keep them available for examination by any authority having jurisdiction.
 
BI-1.jpg

Qualified/ Certified System Technicians

  • Personnel who are factory trained and certified for carbon monoxide detection system design of the specific type and brand of system being designed and who are acceptable to the authority having jurisdiction
  • The system tester shall provide evidence of qualifications and/or certifications when requested by the authority having jurisdiction.
  • Service personnel shall be qualified and experienced in the inspection, testing, and maintenance of systems addressed within NFPA 720.
  • All Technicians will conduct testing and inspection in the accordance with all NFPA 720 guidelines, ensuring worker safety and minimal system down time.

Penalties for NFPA 720 Compliance Failure can Range from:


Some of Our Satisfied & Protected Costumers Include: 


Please contact us for a complimentary system assessment!!!